6 Maintenance Screens
Display item
(3)
Setting by spindle area
Ch / Rotary SW No.
Motor type
Power Supply type
(4)
Setting by servo area
Ch / Rotary SW No.
Motor type
Detector type
Power Supply type
(5)
Guidance display area
Menus
Menu
Param
This writes the parameters based on settings on system setup screen to
setting
NC system.
Next
This displays the next page when guidance display content extends
guide
through multiple pages.
Next
This displays the 5th axis and following in setting by servo area when the
SV axis
total number of axis in the part system exceeds 5.
I - 386
Set the servo I/F connection channel and the rotary switch No. (2-digit value) for each
spindle drive unit. This setting is registered at the "#3031 smcp_no".
1st digit: Servo I/F connection channel.
2nd digit: Rotary switch No.
Set the motor types that are connected to each spindle. Input the values as indicated at the
guidance display area. The input values are not converted to motor types.
Set the power supply types that are connected to each spindle drive unit.
Input the values as indicated at the guidance display area. The input values are then
converted to, and display as, power supply types.
If "0" is displayed, it means "No connection".
Set the servo I/F connection channel and the rotary switch No. (2-digit value) for each servo
drive unit. This setting is registered at the "#1021 mcp_no".
1st digit: Servo I/F connection channel.
2nd digit: Rotary switch No.
Set the motor types that are connected to each servo axis.
Input the values as indicated at the guidance display area. The input values are then
converted to, and displayed as, motor types.
Set the encoder types that are connected to each servomotor.
Input the values as indicated at the guidance display area. The input values are then
converted to, and displayed as, encoder types.
Set the power supply types that are connected to each servo drive unit.
Input the values as indicated at the guidance display area. The input values are then
converted to, and displayed as, power supply types.
If "0" is displayed, it means "No connection".
Indicate the setting content and setting range for the setting item where the cursor is
positioned.
Details
Details
Type
Reference
6.4.1 Writing Initial
A
Parameters
C
C