Initializing Cnc Cpu Internal Data (Clearing Sram Data) - Mitsubishi Electric C70 Setup Manual

Hide thumbs Also See for C70:
Table of Contents

Advertisement

4.2 Initializing CNC CPU Internal Data (Clearing SRAM Data)

(1) With the power OFF, set the CNC CPU module's left rotary switch 1 to "0", right rotary switch 2 to "C". Then turn the
power ON.
(2) The LED changes from "b00" --> ... --> "b80". When "c30" is displayed, clearing is complete. It takes approximately
four seconds.
(3) Turn the power OFF, and set the right rotary switch 2 to "0" (normal setting).
(Note)
By clearing the SRAM, the CNC CPU's Ethernet is set to the following initial values.
<Ethernet's initial setting values of CNC CPU>
- IP address:192.168.1.2
- Subnet mask:255.255.255. 0
- Gateway: 0. 0. 0. 0
- Port No.:64758
- Communication speed:Auto-detect
4.2 Initializing CNC CPU Internal Data (Clearing SRAM Data)