6 Operation Panel Switch Functions

6.16.3 Operation during manual/automatic simultaneous operation

(1) The manual operation and automatic operation feedrates are independent. The acceleration/ deceleration mode
(rapid traverse/cutting feed) and time constants are also independent.
(2) The rapid traverse override is valid for both automatic operation and manual operation. Thecutting feed override
and 2nd cutting feed override are valid only for automatic operation.
However, these will also be valid during manual operation if the manual override method selection signal is ON.
Override cancel is valid only for automatic operation.
(3) Manual interlock is valid for the manual/automatic simultaneous valid axis, and automatic interlock is valid for the
axis in automatic operation.
(4) Manual machine lock is valid for the manual/automatic simultaneous valid axis, and automatic machine lock is valid
for the axis in automatic operation.
(5) The signals in cutting feed and in rapid traverse will follow the automatic operation movement mode.
(6) Movement of the manual/automatic simultaneous valid axis will not stop with the single block stop or feed hold stop.
(7) If the manual/automatic simultaneous valid axis reaches the stored stroke limit or stroke limit, the axis moving in
automatic operation will also stop immediately, and the feed hold state will be entered. In this case, automatic
operation can be restarted by canceling the stored stroke limit or stroke limit with manual operation.
(8) Even if the handle mode is selected for the manual operation mode, the manual/automatic simultaneous function
will be the priority for the axis for which the "Manual/Automatic simultaneous valid n-th axis" signal is ON.
(9) The speed display indicates the following speeds according to the parameter "#1125 real_f".
Function
Manual/automatic simultaneous
operation
Only manual operation
Only automatic operation
II - 32
1
Composite manual and automatic speeds
(The actual feedrates are independent.)
Manual actual feedrate
Automatic actual feedrate
#1125 real_f
0
Automatic F command speed priority
(Manual command speed when there is no
axis moving with automatic operation)
Manual command speed
Automatic F command speed

Advertisement