Mitsubishi Electric E70 Series Instruction Manual page 660

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

P242 = not defined at vrble set
Details
The "=" sign has not been commanded when a variable is defined.
Remedy
- Designate the "=" sign in the variable definition of the program.
P243 Can't use variables
Details
An invalid variable has been specified in the left or right side of an operation expression.
Remedy
- Correct the program.
P244 Invalid set date or time
Details
Date or time was set earlier than current date or time in the system variables (#3011, #3012) when the
system lock was valid.
Remedy
- Date or time cannot be changed.
- Correct the program.
P250 No spec: Figure rotation
Details
Figure rotation (M98 I_J_P_H_L_) was commanded though it is out of specifications.
Remedy
- Check the specifications.
P251 Figure rotation overlapped
Details
Figure rotation command was issued during figure rotation.
Remedy
- Correct the program.
P252 Coord rotate in fig. rotation
Details
A coordinate rotation related command (G68, G69) was issued during figure rotation.
Remedy
- Correct the program.
P260 No spec: Coordinates rotation
Details
A coordinate rotation command was issued though it is out of specifications.
Remedy
- Check the specifications.
P261 G code illegal (Coord rot)
Details
Another G code or a T command has been issued in the block of coordinate rotation command.
Remedy
- Correct the program.
P262 Illegal modal (Coord rot)
Details
A coordinate rotation command has been issued during modal in which coordinate rotation is not
allowed.
Remedy
- Correct the program.
E70 Series Instruction Manual
Appendix 6.12 Program Errors (P)
IV - 127

Advertisement

Table of Contents
loading