3 Setup Screens
<Group 4 display mode> (#1107 Tllfsc = 2)
Display items (L system)
<Group information>
Display item
(1)
Group
(2)
Form
(3)
Life
<Life management data within group>
Display item
(4)
#
(5)
Tool No.
(6)
Comp No.
(7)
Used
(8)
ST
I - 188
Details
Life management group No.
This displays whether to control the currently displayed
group in usage hours or usage count.
This sets the tool life data for the currently displayed
group.
The following tool life data units display based on the
control method.
Usage time: (s)
Usage count: (set)
Details
This displays whether the tool for which the # No. is
highlighted is a life tool (ST=2) or a skip tool (ST=3).
This sets the tool No.
This sets the compensation No.
This sets the usage data at such times as when the tool
is not an unused tool.
This becomes "0" when the usage data is not set.
The following usage data units display based on the
control method.
Usage time: (s)
Usage count: (set)
This sets the tool status.
This becomes "0" when the tool status is not set.
0: Unused tool
1: Used tool
2: Normal life tool
3: Skipped tool
Setting range
1 to 9999
0 : Hours
1 : Times
Usage time:
0 to 99999999 (s)
Usage count:
0 to 999999 (set)
Setting range
1 to 999999
1 to 80
Usage time:
0 to 99999999 (s)
Usage count:
0 to 999999 (set)
Setting can be omitted.
0 to 3
Setting can be omitted.