4.4.12 Program Display Lock C

This function prohibits display and search for machining program C (machine tool builder custom program).
The following influences are received on each screen according to parameter "#1122 pglk_c".
Influences of program display lock parameter on operation screen
Screen operation
Buffer display of operating program
Display when [Program display] highlights
on 2D check full-screen
When the menu [Edit] was pressed
When the main menu [P corr] was pressed
Search from the operation search window
Search from the restart search window
Search from the top search window (of
restart search)
Influences of program display lock parameter on operation screen
Screen operation
The file is automatically opened when
changing the edit screen (Note 1)
When the file is opened by the menu
[Open].
When the main menu [P corr] was pressed
Right side program display when check
main menu is selected
Search from the operation search window
of 2D check
(Note 1) When changing the edit screen, the file opened immediately before or operation searched/check searched is
automatically opened.
1 (Display: ○ Search:×)
The program contents are not displayed. Only "%" is displayed.
The operation message "Program display lock C" appears.The window is opened.
(When the edit lock B or C is valid, edit lock B or C is given to priority.)
The search can be executed.
1 (Display: ○ Search:×)
The program contents are not displayed.
Only "%" is displayed.
The operation message "Program display lock C" appears.The window is not
closed.(When the edit lock B or C is valid, edit lock B or C is given to priority.)
The program contents are not displayed. Only "%" is displayed.
The search can be executed.
E70 Series Instruction Manual
4.4 Program Input/Output
#1122 pglk_c
2 (Display:× Search:×)
The search cannot be executed.The
operation message "Program display
lock C" appears. The window is not
closed. The contents of input area are
not cleared.
#1122 pglk_c
2 (Display:× Search:×)
-(It is not possible to search, so the file is
never automatically opened when
changing the edit screen.)
The search cannot be executed.The
operation message "Program display
lock C" appears. The window is not
closed.