0048 Motor side dtc: Error 5
Details
An error was detected by the detector connected to the main side.
The error details are different according to the connected detector.
- Servo stop method: Dynamic stop
- Spindle stop method: Coast to a stop
[Detector alarm (Servo drive unit)]
- MDS-B-HR(MITSUBISHI) Scale not connected
- AT343, AT543, AT545, ST748(Mitsutoyo) CPU error
- LC193M, LC493M, LC195M, LC495M, LC291M, RCN223M, RCN227M, RCN727M, RCN827M, EIB
Series(HEIDENHAIN) CPU error
- MPRZ Scale(Mitsubishi Heavy Industries) Absolute value detection fault
- SAM/SVAM/GAM/LAM/HAM Series (FAGOR) CPU error
[Detector alarm (Spindle drive unit)]
- MDS-B-HR(MITSUBISHI) Connection error
- EIB Series(HEIDENHAIN) CPU error
(Note) A driver processes all reset types of alarms as "PR". However, "AR" will be applied according to
the detector.
0049 Motor side dtc: Error 6
Details
An error was detected by the detector connected to the main side.
The error details are different according to the connected detector.
- Servo stop method: Dynamic stop
- Spindle stop method: Coast to a stop
[Detector alarm (Servo drive unit)]
- AT343, AT543, AT545, ST748(Mitsutoyo) Photoelectric type overspeed
- LC193M, LC493M, LC195M, LC495M, LC291M, RCN223M, RCN227M, RCN727M, RCN827M, EIB
Series(HEIDENHAIN) Overspeed
- SR75, SR85, SR77, SR87, RU77(Magnescale) Over speed
- RL40N/RA Series (Renishaw) Overspeed error
[Detector alarm (Spindle drive unit)]
- TS5690, TS5691(MITSUBISHI) Overspeed
- EIB Series(HEIDENHAIN) Overspeed
(Note) A driver processes all reset types of alarms as "PR". However, "AR" will be applied according to
the detector.
004A Motor side dtc: Error 7
Details
An error was detected by the detector connected to the main side.
The error details are different according to the connected detector.
- Servo stop method: Dynamic stop
- Spindle stop method: Coast to a stop
[Detector alarm (Servo drive unit)]
- AT343, AT543, AT545,ST748(Mitsutoyo) Static capacity type error
- LC193M, LC493M, LC195M, LC495M, LC291M, RCN223M, RCN227M, RCN727M, RCN827M, EIB
Series(HEIDENHAIN) Absolute position data error
- MPRZ Scale(Mitsubishi Heavy Industries) Gain fault
- SR75, SR85, SR77, SR87, RU77(Magnescale) Absolute position data error
[Detector alarm (Spindle drive unit)]
- MPCI scale(Mitsubishi Heavy Industries) Gain fault
(Note) A driver processes all reset types of alarms as "PR". However, "AR" will be applied according to