Appendix 6 Explanation of Alarms
00A4 Dual signal warning
Details
An input was detected in the signal related to the dual signal.
- Reset method: Automatically reset once the cause of the warning is removed.
00A6 Fan stop warning
Details
A cooling fan in the drive unit stopped.
- Reset method: Automatically reset once the cause of the warning is removed.
00E0 Over regeneration warning
Details
Over-regeneration detection level exceeded 80%.
- Reset method: Automatically reset once the cause of the warning is removed.
00E1 Overload warning
Details
A level of 80% of the Overload 1 alarm state was detected.
- Reset method: Automatically reset once the cause of the warning is removed.
00E4 Set parameter warning
Details
An incorrect set value was detected among the parameters send from the NC in the normal operation.
- Reset method: Automatically reset once the cause of the warning is removed.
00E6 Control axis detach warning
Details
A control axis is being detached. (State display)
- Reset method: Automatically reset once the cause of the warning is removed.
00E7 In NC emergency stop state
Details
In NC emergency stop. (State display)
- Stop method: Deceleration stop enabled
- Reset method: Automatically reset once the cause of the warning is removed.
00E8-00EF Power supply warning
Details
The power supply unit detected a warning. The error details are different according to the connected
power supply unit.
Refer to "Power supply warning".
- Stop method: - (EA: Deceleration stop enabled)
- Reset method: Automatically reset once the cause of the warning is removed.