P10 No. of simultaneous axes over
Details
The number of axis addresses commanded in a block is exceeds the specifications.
Remedy
- Divide the alarm block command into two.
- Check the specifications.
P11 Illegal axis address
Details
The axis address commanded by the program does not match any of the ones set by the parameter.
Remedy
- Correct the axis names in the program.
P20 Division error
Details
The issued axis command cannot be divided by the command unit.
Remedy
- Correct the program.
P29 Not accept command
Details
The command has been issued when it is impossible.
- The normal line control command (G40.1, G41.1, G42.1) has been issued during the modal in which
the normal line control is not acceptable.
- The command has been issued during the modal in which the two-part system simultaneous thread
cutting is not acceptable.
Remedy
- Correct the program.
P30 Parity H error
Details
The number of holes per character on the paper tape is even for EIA code and odd for ISO code.
Remedy
- Check the paper tape.
- Check the tape puncher and tape reader.
P31 Parity V error
Details
The number of characters per block on the paper tape is odd.
Remedy
- Make the number of characters per block on the paper tape even.
- Set the parameter parity V selection OFF.
P32 Illegal address
Details
An address not listed in the specifications has been used.
Remedy
- Correct the program address.
- Correct the parameter settings.
- Check the specifications.
P33 Format error
Details
The command format in the program is not correct.
Remedy
- Correct the program.
E70 Series Instruction Manual
Appendix 6.12 Program Errors (P)
IV - 113