Diagnosis Data Collection Setting Screen - Mitsubishi Electric E70 Series Instruction Manual

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

MITSUBISHI CNC
6 Maintenance Screens

6.8 Diagnosis Data Collection Setting Screen

The NC automatically collects diagnosis data based on the "Sampling spec" and "Collecting data select" settings
specified at this screen.
(1)
(2)
Display items
Display item
(1)
State
History data
Sampling data
(2)
Sampling spec
System
Spindle
Servo
I - 408
Display the history data and sampling data collection status.
Display the history data collection status.
History collecting: History data collection is in progress.
History stop: History data collection is stopped.
Display the sampling data collection status.
Sampling: Sampling data collection is in progress.
Sampling stop: Sampling data collection is stopped.
Sampling invalid: Sampling data collection is disabled.
Specify the part system, spindle, and servo axes where sampling data is to be collected.
Specify the part systems where sampling data is not to be collected.
When "0" is set, sampling is carried out for all part systems.
This setting is ignored if a non-existent part system is specified.
(The E70 Series is one-part system control.)
Specify the spindle where sampling data is not to be collected.
When "0" is set, sampling is carried out for all spindles.
This setting is ignored if a non-existent spindle is specified.
Specify the servo axes where sampling data is not to be collected.
When "0" is set, sampling is carried out for all axes.
This setting is ignored if a non-existent servo axis is specified.
Details
(3)

Advertisement

Table of Contents
loading