Mitsubishi Electric E70 Series Instruction Manual page 198

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

<L system>
■ Tool life management I --- Tool life data display
The tool usage time and usage count indicated in the program is accumulated, and the usage status for that tool is
monitored.
Tool life management can be performed for a maximum of 80 tools (tool Nos. 1 to 80).
(a) Time based control
The cutting time (G01, G02, G33 etc.) after performing the tool selection command (T) is calculated in the tool
usage time corresponding to the designated tool.
A warning is issued if the usage time at the time the tool selection command is performed reaches the life time.
(b) Usage count based control
The tool usage count corresponding to the designated tool No. increases each time the tool selection command (T)
is performed.
A warning is issued if the usage count at the time the tool selection command is performed exceeds the life time.
■ Tool life management II --- Tool life data display / registration group list display
The life (usage time, usage count) of each tool is controlled, and if the life is reached, the same spare tools are selected
and used one by one from the group to which that tool belongs.
- Group count : Multi-part system spec. : max. 80 groups
- No. of tools in group: Max. 16
The tool life management related parameters (basic shared parameters) are shown below.
#
Name
T_Ltyp
1096
Tool life management type
T_Life
1103
Enable tool life management
Tllfsc
(For L system only)
1107
Tool life management
Display screen division
The tool life management screen is made up of the group list display screen and the life management data screen.
(There is no group list display screen in L system tool life management 1. Only the life management data screen exists.)
Refer to the following sections for details of the display contents, menus, and an explanation of the operations for each
screen.
"3.5.1 Displaying the Group List"
"3.5.2 Displaying the Life Management Data in Group Units (M system)"
"3.5.3 Displaying the Life Management Data (L system: Tool life management I)"
"3.5.4 Displaying the Tool Life Management Data in Group Units (L system: Tool life management II)"
Setting
1, 3
Tool life management I
2
Tool life management II
0
The tool life management is not performed.
1
The tool life management is performed.
Set the no. of groups displayed at the tool life management II (L series) screen.
0
Displayed no. of groups: 1, Max. No. of registered tools: 16
1
Displayed no. of groups: 2, Max. No. of registered tools: 8
2
Displayed no. of groups: 4, Max. No of registered tools: 4
E70 Series Instruction Manual
3.5 Tool Life Management
Details
I - 173

Advertisement

Table of Contents
loading

Table of Contents