M01 Turn stop in normal line cntrl 0118
Details
The turning angle at the block joint exceeded the limit during normal line control.
In normal line control type I:
"#1523 C_feed (Normal line control axis turning speed)" has not been set.
In normal line control type II:
When turning in the inside of the arc, the set value for "#8041 C-rot. R" is larger than the arc radius.
Remedy
- Correct the program.
- Correct the "#1523 C_feed (Normal line control axis turning speed)" setting.
- Correct the "#8041 C rot. R" setting.
M01 Reverse run impossible 0119
Details
Either of the following conditions occurred:
- there is no block to run backward.
- eight blocks has been continued without any travel command.
Remedy
- Execute forward run to clear the alarm.
- Reset to clear the alarm.
M01 In synchronous correction mode 0120
Details
The synchronous correction mode switch was pressed in non-handle mode.
Remedy
- Select the handle or manual arbitrary feed mode.
- Turn OFF the correction mode switch.
M01 No synchronous control option 0121
Details
The synchronous control operation method was set (with R2589) while no synchronous control option
was provided.
Remedy
- Set "0" for "synchronous control operation method".
M01 Computer link B not possible 0123
Details
Cycle start was attempted before resetting was completed.
Computer link B operation was attempted at the 2nd or further part system in a multi-part system.
Remedy
- Perform the cycle start after resetting has been completed.
- Set "#8109 HOST LINK" to "0" and then set to "1" before performing the cycle start.
- Computer link B operation cannot be performed at the 2nd or further part system in a multi-part
system.
M01 X/Z axes simultaneous prohibit 0124
Details
The basic axis corresponding to the inclined axis was started simultaneously in the manual mode while
the inclined axis control was valid.
Remedy
- Turn the inclined axis and basic axis start OFF for both axes. (This is also applied for manual/
automatic simultaneous start.)
- Disable the basic axis compensation, or command it to axes one by one.