Appendix 6 Explanation of Alarms
P295 WHILE/GOTO in tape
Details
There is a WHILE or GOTO statement on the tape during tape operation.
Remedy
- Apply memory mode operation instead of tape mode that does not allow the execution of the
program with a WHILE or GOTO statement.
P296 No address (macro)
Details
A required address has not been specified in the user macro.
Remedy
- Correct the program.
P297 Address-A error
Details
The user macro does not use address A as a variable.
Remedy
- Correct the program.
P298 G200-G202 cmnd in tape
Details
User macro G200, G201, or G202 was specified during tape or MDI mode.
Remedy
- Correct the program.
P300 Variable name illegal
Details
The variable names have not been commanded properly.
Remedy
- Correct the variable names in the program.
P301 Variable name duplicated
Details
A duplicate variable name was found.
Remedy
- Correct the program so that no duplicate name exists.
P310 Not use GMSTB macro code
Details
G, M, S, T, or B macro code was called during fixed cycle.
Remedy
- Correct the program.
- Correct the parameter settings.
P350 No spec: Scaling command
Details
The scaling command (G50, G51) was issued though it is out of specifications.
Remedy
- Check the specifications.
P360 No spec: Program mirror
Details
A mirror image (G50.1 or G51.1) command has been issued though the programmable mirror image
specifications are not provided.
Remedy
- Check the specifications.
IV - 130