Mitsubishi Electric E70 Series Instruction Manual page 92

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

Operation method (search during single block stop)
Cursor position search can be operated during single block stop when parameter "#11039 Cusr pos srch Tyoe" is "1".By
pressing [Edit] menu during single block stop, single block stop position becomes top of the program display.
(1)
Pause automatic operation with single block stop.
(2)
Press the [Edit].
Move the cursor to the block to carry out the cursor
(3)
position search.
(4)
Press [INPUT] key.
(Note 1) Blocks lower than the point of the single block stop only are eligible for cursor position search designation
during single block stop. "Search error" will display and the search will fail when cursor position search is
attempted at an already executed block.
(Note 2) The blocks between single block stop position and search position block will be ignored when cycle start is
operated after cursor position search is operated during single block stop.
(Note 3) If cursor position search is commanded at a block that causes a program error, the block of the single block
stop, instead of the cursor position search target block, will appear on the top of program buffer display upon
automatic start up.
(Note 4) If cursor position search is commanded at a block that comes later than a fixed cycle while stopped with single
block stop in the midst of the fixed cycle, the cursor position search target block will appear on the top of the
program buffer display. However, automatic operation will start from the top of the remaining of the fixed
program, and after finishing the fixed cycle, will move on to executing the cursor search target program.
E70 Series Instruction Manual
The "Prog edit" window appears. The block where the
operation is stopped due to single block stop is displayed on
the top.
Be noted, though, that when implementing mass-editing, the
block where cursor is positioned will not always be displayed
on the top if the program length is 16 lines or less or if the
cursor is at the last or first block of the program. In these cases,
the first or the last block of the program comes to the top of the
display.
If the operation has bee stopped in a subprogram, that
subprogram is displayed.
The search will operate by single block stop position with
top.During the search "Searing" will display blinking.When the
search is completed, "Search completed" is displayed.
2.4 Program Edit