Appendix 7.2 Graphic Display-Related Operation Messages - Mitsubishi Electric E70 Series Instruction Manual

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

Appendix 7.2 Graphic Display-related Operation Messages

Message
Searching
Search error
Executing automatic operation
Setting error
Execute operation search
Checking
Check stopped
Work form is illegal
Push [Check reset] menu
Executing trace
Program check completed
Reset complete
Tool interfere with work
Program checking
Executing reset operation
Executing trace(tip posn)
Executing BG simulation
Draw library inside error (n)
Program check not possible
Execute check search
Solid check disabled (memory shortage)
Executing scale
Appendix 7.2 Graphic Display-related Operation Messages
- The check search is being executed.
- Could not find the designated ONB number.
Review the ONB number or machining program settings.
- The check search could not be completed correctly.
- When the parameter (#9005) of the tape mode port was set out of the range or
when the port was not connected, an operation search of NC serial was
performed.
- An attempt was made to perform operations such as parameter, tool
compensation amount data and coordinate system offset settings during
automatic operation. (Input/output also possible during automatic operation)
- The machining program and MDI data that the operator is attempting to edit
cannot be edited during automatic operation.
- It is not possible to be executed a check search or check start-up during
automatic operation.
- An attempt was made to set the verify stop position during automatic operation.
- The directory name exceeded the display range.
A directory path for which the entire directory cannot be displayed cannot be
designated in the directory name area.
- The check search is not possible because ONB number is not designated.
- A non-existent axis name or setting that does not exist in the format was made
when making the display mode settings.
Set using an existing axis name.
- Incorrect tool No. was specified at the execution of tool clear.
- The program is not searched.
Execute the operation search.
- The program check is being executed.
- The program check is being stopped.
- A workpiece is not drawn correctly because the two or more workpiece widths
are set to "0".
- An error occurred in the graphic check.
Press the [Check reset] menu key to reset the error.
- The trace mode is valid.
- The trace in the program check completed with an M02/M30 code.
- The program check was reset.
- The tool contacted the workpiece when performing rapid traverse (G0)
movement with the interference check enabled.
- The program check is being executed.
- The program check is being reset.
- The tip position trace mode is valid.
- The back ground simulation is being executed.
- Contact the service center.
- Graphic check was attempted during the Computer link B operation.
- The program check is disabled. Execute the check search.
- The 3D program check is disabled due to the memory shortage.
Separate the programs and execute the check drawing again.
Press the menu [Work init] once before performing the check drawing again.
Scale is being automatically adjusted.
E70 Series Instruction Manual
Details
IV - 147

Advertisement

Table of Contents
loading

Table of Contents