MITSUBISHI CNC
2 Monitor Screens

2.3.1 Main Screen

The type 1 and type 2 restart search can be executed from the Main screen.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Display items
Display item
Device and directory
(1)
display
(2)
Research position
Last executed program
(3)
position
(4)
Restart type
Position when restart
(5)
search is completed
Remaining distance
(6)
when restart search is
completed
(7)
Input area
I - 50
This displays the device and directory where the searched machining program is located.
This displays the researched main program position (program No., sequence No., block
No.).
(Note)When the sequence No. exceeds six digits, only lower six digits is displayed.
This displays the last executed program position (the program number, the sequence
number, the block number and the number of repetition). Actual restart position may not be
same as the last executed program position when executing the restart search with restart
type 1 because it is updated by the timing of machine stop operation after the automatic
operation (NC reset, emergency stop, single block stop and feed hold stop).
This displays the restart search type.
This displays the position on the local coordinate system when the restart search is
completed.
This displays the remaining distance when the restart search is completed.
This displays the input key details.
Details