【#8884】 Subbro stor D2: dev
Select the storage destination (device) for the subprogram.
M:Memory, G:HD(Note), F:FD(Note), R:Memory card, D:Data server(Note)
(Note) This is available only with M700/M700VW Series.
When D2 is designated at a subprogram call, the subprogram to be called will be searched from the
device selected with this parameter.
(Example) M98 P (program No.), D2
-> Device: "#8884 Subpro stor D2: dev" device
Directory: "#8885 Subpro stor D2: dir" directory
The device and directory above will be searched.
(Note 1) When the called subprogram is not found in the selected storage destination, a program
(Note 2) When D0 to D4 is not designated at a subprogram call, the subprogram will be searched
【#8885】 Subpro stor D2: dir
Select the storage destination (directory) for the subprogram.
When D2 is designated at a subprogram call, the subprogram to be called will be searched from the
directory selected with this parameter.
Refer to "#8884 Subpro stor D2: dev".
---Setting range---
Directory 48 characters
【#8886】 Subbro stor D3: dev
Select the storage destination (device) for the subprogram.
M:Memory, G:HD(Note), F:FD(Note), R:Memory card, D:Data server(Note)
(Note) This is available only with M700/M700VW Series.
When D3 is designated at a subprogram call, the subprogram to be called will be searched from the
device selected with this parameter.
(Example) M98 P (program No.), D3
-> Device: "#8886 Subpro stor D3: dev" device
Directory: "#8887 Subpro stor D3: dir" directory
The device and directory above will be searched.
(Note 1) When the called subprogram is not found in the selected storage destination, a program
(Note 2) When D0 to D4 is not designated at a subprogram call, the subprogram will be searched
【#8887】 Subpro stor D3: dir
Select the storage destination (directory) for the subprogram.
When D3 is designated at a subprogram call, the subprogram to be called will be searched from the
directory selected with this parameter.
Refer to "#8886 Subpro stor D3: dev".
---Setting range---
Directory 48 characters
error will occur.
from the memory.
error will occur.
from the memory.