Mitsubishi Electric E70 Series Instruction Manual page 720

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

【#8123】 H-spd retract ON
Select whether to enable the drilling cycle at high-speed retract in fixed cycle for drilling.
0: Disable
1: Enable
【#8124】 Mirr img at reset
Select the operation type of the mirror image by parameter setting and the mirror image by external
input.
0: The current mirror image is canceled, and new mirror image will start with the machine position
1: The mirror center is kept to continue the mirror image.
【#8125】 Check Scode in G84
Select how to operate when there is no S command in synchronous tapping block.
0: Use the spindle function modal value as S-command value.
1: Output a program error.
【#8126】 Disable op tone
Select whether to disable keyboard/touch panel operation tones.
0: Enable the operation tones
1: Disable the operation tones
(Note)This setting is valid only for M700VS/M70V/M70/E70 Series.
【#8127】 R-Navi manu F coor
Select the initial value of the coordinate system for a manual feed while a machining surface is
selected in the R-Navi function.
0: Feature coordinate system
1: Machine coordinate system
【#8129】 Subpro No. select
Select the subprogram No. to be called preferentially in subprogram control.
0: Commanded program No.
1: Four-digit program No. beginning with O No.
2: Eight-digit program No. beginning with O No.
(Note)The program to be called in user macro, figure rotation, macro interruption and compound
【#8135】 G5P4 single block
Single block stop is disabled during direct command mode.
0: Not disable single block stop
1: Disable single block stop
【#8145】 Validate F1 digit
Select whether to execute the F command with a 1-digit code command or with a direct numerical
command.
(The same value as "#1079 F1digt" will be reflected. When either setting changes, the other will
change accordingly.)
0: Direct numerical command (command feedrate during feed per minute or rotation)
1: 1-digit code command (with the feedrate specified by the parameters "#1185 spd_F1" to "#1189
【#8154(PR)】
Not used. Set to "0".
【#8155】 Sub-pro interrupt
Select the method for the user macro interrupt.
(The same value as "#1229 set01/bit0" will be reflected. When either setting changes, the other will
change accordingly.)
0: The user macro interrupt of macro type
1: The user macro interrupt of sub-program type
at reset as the mirror center.
type fixed cycle also follows this setting.
spd_F5")
E70 Series Instruction Manual
IV - 187