Appendix 7.6 Data Input/Output-related Operation Messages

Message
Overwrite this file?(Y/N)
Over run error
Memory over
Edit lock B
Edit lock C
Can't make directory on this device
Designated file does not exist
The file name is a directory
Change complete
Changing
Erase complete
Erase ended. Some file not erased
Verify error
Compare error. Compare next file?(Y/N)
Compare complete
Verifying
The file already exists
Can't erase designated file
Can't rename designated file
Can't condense designated file
Designated file is locked
Can't open file for dev A
Can't open file for dev B
Can't read file for dev A
Can't read file for dev B
Appendix 7.6 Data Input/Output-related Operation Messages
- Message to confirm the overwriting.
[Y] or [INPUT]: Overwrite the file.
[N]: Do not overwrite the file.
- The buffer overran or overflowed.
- The program cannot be written, because the memory capacity will be exceeded.
- It is not possible to change machining program B (8000 to 8999: user standard
subprogram) or machining program C (9000 to 9999: machine tool builder
custom program) as edit lock B is enabled.
- It is not possible to change machining program C (9000 to 9999: machine tool
builder custom program) as edit lock C is enabled.
- Creation of a directory was attempted for a device that cannot have a directory.
- The file specified in device A, and B does not exist.
- The applicable file does not exist in the specified directory.
- A directory was designated for the file transfer. A directory cannot be
transferred.
- The data conversion completed correctly.
- The data is being converted.
- The file has been erased.
- The file erasing completed, but there are some files that could not be erased.
- An error occurred when performing a file verification.
- Message to confirm the comparison
[Y] or [INPUT]: Compare the next file.
[N]: Do not compare the next file.
- The data comparison completed.
- The data is being compared.
- The input file name already exists.
- The file name after renaming already exists.
- Erasing was attempted of a file that cannot be erased.
- An attempt was made to change the name of a file that cannot be renamed.
- Condensing of a file that cannot be condensed was attempted.
- Changing was attempted of a locked file.
- Could not find the file for device A.
Or, the file is in a state in which it cannot be accessed.
- Could not find the file for device B.
Or, the file is in a state in which it cannot be accessed.
- Could not read in the file for device A.
Recheck the connection status for device A or the input/output parameter
setting.
- Could not read in the file for device B.
Recheck the connection status for device B or the input/output parameter
setting.