Mitsubishi Electric E70 Series Instruction Manual page 585

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 6 Explanation of Alarms
M92 IGNORE INT.LOCK
Details
Manual tool length measurement Interlock temporally canceled
"M01 Operation error 0005" and "M01 Operation error 0019", which occur at manual tool length
measurement, are temporally canceled. When a tool has contacted a sensor and "M01 Operation
error 0019" has occurred, tool escape is enabled by temporarily turning ON the interlock cancel
request. This alarm notifies that the interlock is disabled in the meantime.
Remedy
After carrying out the tool escape from the sensor, turn OFF the interlock temporary cancel signal for
manual tool length measurement.
IV - 52

Advertisement

Table of Contents