Mitsubishi Electric E70 Series Instruction Manual page 748

Hide thumbs Also See for E70 Series:
Table of Contents

Advertisement

【#9213】 DEV1 EIA OUTPUT
Select ISO or EIA code for data output.
In data input mode, the ISO and EIA codes are identified automatically.
0: ISO code output
1: EIA code output
【#9214】 DEV1 FEED CHR.
Set the length of the tape feed to be output at the start and end of the data during tape output.
---Setting range---
0 to 999 (characters)
【#9215】 DEV1 PARITY V
Select whether to perform the parity check for the number of characters in a block at the input of
data.
At the output of data, the number of characters is always adjusted to for the parity check.
0: Not perform parity V check
1: Perform parity V check
【#9216】 DEV1 TIME-OUT (sec)
Set the time out time to detect an interruption in communication.
Time out check will not be executed when set to "0".
---Setting range---
0 to 30 (s)
【#9217】 DEV1 DR OFF
Select whether to enable the DR data check in data I/O mode.
0: Enable
1: Disable
【#9218】 DEV1 DATA ASCII
Select the code of the output data.
0: ISO/EIA code (Depends on whether #9113, #9213, #9313, #9413 or #9513 EIA output
1: ASCII code
【#9219】 DEV1 INPUT TYPE
Select the mode for input (verification).
0: Standard input (Data from the very first EOB is handled as significant information.)
1: EOBs following the first EOB of the input data are skipped until data other than EOB is input
【#9220】 DEV1 OUT BUFFER
Select the buffer size of the output data which is output to output device using NC side serial port.
If the output device has a transmission error (overrun error), decrease the buffer size with this
parameter.
If the buffer size is decreased, output time will prolong according to the size.
0: 250 bytes (default)
1: 1 byte
2: 4 byte
3: 8 byte
4: 16 byte
5: 64 byte
【#9221】 DEV1 EIA CODE [
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code "
[ ".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
parameter is set up.)
E70 Series Instruction Manual
IV - 215

Advertisement

Table of Contents
loading

Table of Contents