Step 2: Configure Test Set And Ue Parameters; Set Up The Cell Parameters; Set Generator Info Parameters - Agilent Technologies 8960 Series Reference Manual

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

Step 2: Configure Test Set and UE Parameters

Step 2: Configure Test Set and UE Parameters
In this step you configure the parameters that allow a connection to be made between the test set and UE.

"Set up the Cell Parameters"

"Set Generator Info Parameters"

"Set Uplink Parameters"
"Set up Call Parameters"
"Set Uplink Channel Levels"
"Set up Call Control"
Set up the Cell Parameters
The example below illustrates how to set up the cell parameters. You can set cell parameters like the MCC,
MNC, and LAC as well as specify whether single or repeat paging shoud be used when paging the UE.
The operating mode must be Cell Off to set up the cell parameters. See
you do not set the operating mode to Cell Off, the test set generates the following error:
Command Rejected. Change Not Allowed in Active Cell Mode.
320
! Cell Parameters
330
OUTPUT Testset;"CALL:LAC 30865" !Correct LAC avoids Location Update
340
OUTPUT Testset;"CALL:MCC 234"
350
OUTPUT Testset;"CALL:MNC 56"
360
OUTPUT Testset;"CALL:PAG:REP:STAT:WCDMA ON
Set Generator Info Parameters
There are several downlink physical channels and an AWGN (Additive White Gaussian Noise) source which
you can configure. You can set the power level of each physical channel (relative to cell power) and the absolute
power level of the AWGN source. You can also specify that these channels use different power levels once an
Active Cell connection has been established. For some of the physical channels you can also specify the
channelization code. The downlink channel codes and levels required the operating mode be set to Cell Off for
configuring.
370
! Generator Info
380
!
-Downlink Channel Codes
390
OUTPUT Testset;"CALL:SCOD:PRIM 0"
400
OUTPUT Testset;"CALL:SRB:CCH:DED:BPS3400:CCOD CODE12"
410
OUTPUT Testset;"CALL:CCPC:SEC:CCOD CODE7"
420
OUTPUT Testset;"CALL:PICH:CCOD CODE16"
430
OUTPUT Testset;"CALL:AICH:CCOD CODE10"
440
OUTPUT Testset;"CALL:DPCH:RMC12:CCOD CODE9"
450
!
-Downlink Channel Levels
460
OUTPUT Testset;"CALL:CPIC -4.8"
470
OUTPUT Testset;"CALL:CCPC:PRIM -7.1"
480
OUTPUT Testset;"CALL:CCPC:SEC -6.9"
490
OUTPUT Testset;"CALL:PICH -9.9"
98
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_prog_getting_started_step2.fm
"Set Operating Mode" on page