Agilent Technologies 8960 Series Reference Manual page 394

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

RFANalyzer
RFANalyzer:MANual:POWer[:SELected]
Function
Sets/queries the receiver expected input power when the test set's receiver input power control
mode is set to manual. See
The optional [:SELected] keyword in this command specifies that the expected input power
setting being queried applies to the current system type.
The test set's receiver power control mode is set by the
command.
The test set's measuring receiver will consider any amplitude offsets that are defined along with
this setting to calculate input power range settings.
Setting
Range: Test application and system type dependent (approximately -25 to +43 dBm).
Resolution: 0.01 dBm
Query
Range: Test application and system type dependent (approximately -25 to +43 dBm).
*RST setting
-75 dBm
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:POWER:SELECTED 24 DBM" !Sets the manual power control mode
expected input power level for the currently selected system type to 24 dBm.
RFANalyzer:MANual:POWer:FDD
Function
Sets/queries the sets the measurement and demod receivers expected input power when UTRA
FDD is the current system type and the receiver input power control is set to Manual. See
Control (Except for CW Mode)"
The test set's receiver power control mode is set by the
command.
The test set's measuring receiver will consider any amplitude offsets that are defined along with
this setting to calculate input power range settings.
Setting
Range: -129 to +80 dBm (-79 dBm to +30 dBm actual hardware range with amplitude offset = 0)
Resolution: 0.01 dBm
Query
Range: -129 to +80 dBm (-79 dBm to +30 dBm actual hardware range with amplitude offset = 0)
*RST setting
0 dBm
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:POWER:FDD 24 DBM"
!Sets the manual power control mode expected input power level for the FDD system type to
!24 dBm.
394
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_hpib_rfanalyzer.fm
"Power Control (Except for CW Mode)"
.
.
"RFANalyzer:CONTrol:POWer:AUTO"
"RFANalyzer:CONTrol:POWer:AUTO"
"Power

Advertisement