CALL:STATus:CELL:SYSTem[:TYPE]?
Function
Queries the current system type that the test set is currently emulating.
When the test set is in active cell operating mode (see
system type is selected by the
not available in the initial W-CDMA test application release.)
When the test set is in any test mode operating mode (see
operating mode, this command will return the corresponding system type.
Query
Range: FDD|CW
*RST Setting
FDD
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:STATUS:CELL:SYSTEM:TYPE?"
CALL:STATus:CPIChannel[:LEVel]?
Function
Queries the current common pilot channel's power.
Query
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
*RST Setting
-4.8 dB
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:STATUS:CPICHANNEL:LEVEL?"
CALL:STATus:CPIChannel:STATe?
Function
Queries the current state of the common pilot channel.
Query
Range: 1|0
*RST Setting
1 (on)
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:STATUS:CPICHANNEL:STATE?"
"CALL[:CELL]:OPERating"
"CALL[:CELL]:SYSTem"
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_hpib_call_status.fm
command. (Active cell operating mode is
"CALL[:CELL]:OPERating"
CALL:STATus
) the current
) or CW
299