CALL:CONNected:DROP:TIMer[:STATe]:WCDMa
Function
Sets/queries the call drop timer for the WCDMA format, whether or not that format is active. The
call drop timer indicates loss of uplink. This timer also determines when the demodulation of the
uplink has been unsuccessful for a fixed period.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
1 (on)
Requirements
Test Application Revision: A.02 and above.
Programming Example
OUTPUT 714;"CALL:CONNECTED:DROP:TIMER:STATE:WCDMA 0"
CALL:CONNected:CCPChannel:PRIMary[:SLEVel]
Function
Sets/queries the power offset of the primary common control physical channel to use while a call
is connected. This command sets the power offset level and turns on the power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this
setting while in this mode results in the following error message: "Command Rejected. Change
Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
Setting
Range: -20.00 dB to 0 dB
Resolution: 0.01
Query
Range: -20.00 dB to 0 dB
Resolution: 0.01
*RST Setting
-5.35 dB
Requirements
Test Application Revision: A.02 and above.
Programming Example
OUTPUT 714;"CALL:CONNECTED:CCPCHANNEL:PRIMARY:SLEVEL -7" !Sets P-CCPCH connected power offset.