Agilent Technologies 8960 Series Reference Manual page 283

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

CALL:PICHannel[:SLEVel]
Function
Sets/queries the page indicator channel's initial power offset, and turns its state to ON.
This setting cannot be changed while in active cell operating mode (when available). Attempting
to change this setting while in this mode results in the following error message: "Command
Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when
changing this value.
Setting
Range: - 20 to 0 dB
Resolution: 0.01
Query
Range: -20 to 0 dB
Resolution: 0.01
*RST Setting
-9.9 dB
Requirements
Test Application Revision: A.02 and above
Programming Example
OUTPUT 714;"CALL:PICHANNEL -12DB"
CALL:PICHannel:CCODe
Function
Sets/queries the page indicator channel's channelization code.
This setting cannot be changed while in active cell operating mode (when available). Attempting
to change this setting while in this mode results in the following error message: "Command
Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when
changing this value.
Setting
Range: CODE11|CODE12|CODE13|CODE14|CODE15|CODE16|CODE17
Query
Range: CODE11|CODE12|CODE13|CODE14|CODE15|CODE16|CODE17
*RST Setting
CODE16
Requirements
Test Application Revision: A.01 (codes 14--17)
Test Application Revision: A.02 and above (added codes 11--13)
Programming Example
OUTPUT 714;"CALL:PICHANNEL:CCODE CODE17"