CALL:TOTal:POWer

CALL
:TOTal
"Diagram Conventions" on page 210
CALL:TOTal:POWer[:AMPLitude]?
Function
Queries the total RF power settings for the current system type.
Total RF Power is the sum of cell power and AWGN power
Query
Range:
• -170 dBm/3.84 MHz to +37dBm/3.84 MHz, 9.91 E+37
(-120 dBm/3.84 MHz to -13 dBm/3.84 MHz actual hardware range with amplitude offset = 0)
The actual power range is defined by adding the value of the associated amplitude offset to
the range above. For example, if amplitude offset is -3.5 dB, then the power range will be
-123.5 dBm/3.84 MHz to -16.5 dBm/3.84 MHz.
Resolution: 0.01 dBm/3.84 MHz
*RST Setting
9.91 E+37
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:TOTAL:POWER:AMPLITUDE?"
CALL:TOTal:POWer:STATe?
Function
Queries the total RF power state for the current system type.
The total RF power state is 1 (on) if either cell power or AWGN power is on.
The return value for this query is not necessarily the total power state at the moment this
command is processed by the test set. This command may return a state that has been requested
of the test set, but that has been pended or delayed for some reason. To query the power state of
the test set at the moment, use the
Query
Range: 1|0
*RST Setting
0 (off)
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:TOTAL:POWER:STATE?"
:POWer
[:AMPLitude]
:STATe
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_hpib_call_total_power.fm
"CALL:STATus:TOTal:POWer:STATe?"
CALL:TOTal:POWer
? (returns num value)
? (returns 1|0)
command.