Process for Making a Base Station Originated Call Figure 7. Process for Making a Base Station
Originated Call
It is not necessary for you to send the CALL:CONN:TIM and CALL:CONN:ARM commands as
NOTE
they are automatically sent by the test set during a base station originated call or base station
release.
Example 10. Programming Example
OUTPUT Test_set;"CALL:PAG:PNUM '0000574016'"! Set paging number
OUTPUT Test_set;"CALL:PAG:REP ON" ! Set paging repeat state
Start
Set paging number.
Set paging repeat
state.
Originate a call.
Send CALL:CONN?
query.
Enter response from
CALL:CONN? query.
No
Call connected?
Yes
Proceed with control
program.
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_prog_generic_step4.fm
Send CALL:END
command.
Invoke error
handler.
Step 4: Make Connection