Agilent Technologies 8960 Series Reference Manual page 267

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

CALL:FDDTest:PICHannel:LEVel
Function
Sets/queries the page indicator channel's test mode power offset during FDD test mode operation.
This command sets the power offset level and turns on the power offset.
Setting
Range: -20.00 dB to 0 dB
Resolution: 0.01
Query
Range: -20.00 dB to 0 dB
Resolution: 0.01
*RST Setting
-8.3 dB
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:CPICHANNEL:LEVEL -5"
CALL:FDDTest:PICHannel:STATe
Function
Sets/queries the page indicator channel's state during FDD test mode operation.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
1 (on)
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:CPICHANNEL:STATE OFF"
CALL:FDDTest:TFCIndicator
Function
Sets/queries the transport format combination indicator (TFCI) during FDD test mode operation.
The TFCI is a hexadecimal string of up to 12 characters. An error message is displayed if the user
attempts to enter more characters than fit into the string.
Setting
Range: 0x000 to 0x3FF
Query
Range: 0x000 to 0x3FF
*RST Setting
0x000
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:TFCINDICATOR 0x2DE"
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_hpib_call_fddtest.fm
CALL:FDDTest
267

Advertisement

Table of Contents
loading

Table of Contents