Call:cpichannel - Agilent Technologies 8960 Series Reference Manual

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

CALL:CPIChannel

CALL
:CPIChannel
"Diagram Conventions" on page 210
CALL:CPIChannel[:SLEVel]
Function
Sets/queries the common pilot channel's initial power offset. This command sets the power offset
level and turns on the power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this
setting while in this mode results in the following error message: "Command Rejected. Change
Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
Setting
Range: -20.00 dB to 0 dB
Resolution: 0.01
Query
Range: -20.00 dB to 0 dB
Resolution: 0.01
*RST Setting
-4.8 dB
Requirements
Test Application Revision: A.02 and above.
Programming Example
OUTPUT 714;"CALL:CPICHANNEL:SLEVEL -10"
<sp><num value>[DB]
[:SLEVel]
? (returns num value)
:LEVel
<sp><num value>[DB]
? (returns num value)
:STATe
<sp>1|0N|0|0FF
? (returns 1|0)
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_hpib_call_cpichannel.fm