Table 7.
Error Message
+211 Call Disconnected. No Response to registration
request.
+212 Call Disconnected. Max No. RLC Retransmissions
Exceeded
+213 Call Disconnected. RLC Reset Received
+214 Command Rejected. Change Not Allowed in Active
Cell Mode
+215 Call Disconnected. No Response to Page
+222 No Physical Channel Reconfiguration Complete
Table 8. FDD Call Processing Errors
+217 Performance not specified for UL/DL frequency offset
< 30 MHz
+218 FDD Settings Deferred: Cell power and AWGN power
> 10 dB apart.
+220 Command Rejected. UL Power Control is active
+221 FDD Test Mode Settings Deferred: Sum of code channel
power levels > 0 dB
+223 Active Cell Mode Initial Settings Deferred: Sum of code
channel power levels > 0 dB
+224 FDD Test Mode Settings Deferred: One or more code
channel power levels > 30 dB below total RF power
+225 Active Cell Mode Initial Settings Deferred: One or more
code channel power levels > 30 dB below total RF power
+226 Active Cell Mode Connected Settings Deferred: Sum of
code channel power levels > 0 dB
Error Message
+200 through +299 Error Message Descriptions
The call is dropped by the test set as a result of the UE
not responding to a registration request message.
The single RLC retransmission attempted by the test set
is not acknowledged by the UE.
The single RLC retransmission request from the test set
resulted in a second incorrectly received PDU.
This setting can not be changed by the user while the Cell
Operating Mode is "Active Cell".
The test set did not receive either a valid PRACH
preamble or the "RRC Connection Request" message
within 2 seconds.
The uplink DPCH is found but the appropriate
"Reconfiguration Complete" message is not received from
the UE after a sending a physical channel
reconfiguration. However, the test set assumes the
reconfiguration was successful and attempts to maintain
the connection.
Performance is not specified when the difference in
the uplink and downlink frequencies is less than
30 MHz.
AWGN and Cell Power settings must be within 10 dB
of each other.
Step up or step down TPC bit patterns can not be sent
when uplink closed loop power control is active.
The sum of the code channels cannot exceed 0 dB.
Reduce one or more channel levels.
The sum of the code channels cannot exceed 0 dB.
Reduce one or more channel levels.
The power of at least one code channel is more than
30 dB below the total RF power, exceeding the test
set's limits.
The power of at least one code channel is more than
30 dB below the total RF power, exceeding the test
set's limits.
The sum of the code channels cannot exceed 0 dB.
Reduce one or more channel levels.