Step 1: Set Up the Test Set

Step 1: Set Up the Test Set
In this step you initialize the test set and set up general operating conditions.

"Initialize the Test Set"

"Set Up General Operating Conditions"

Initialize the Test Set
Fully Preset the Test Set
It is important to start each production session with the test set in a known state.
Sending the *RST command resets all parameters to their default values, ends all
measurement processes, and sets all measurement triggers to single.
Clear the Error Queue
At the start of each production session it is useful to clear the error queue so that you
know any messages logged are relevant to the current production session.
Programming Example
210
OUTPUT Testset;"*RST"
220
OUTPUT Testset;"*CLS"
Set Up General Operating Conditions
Turn Debugger On
The debugger is useful while you are developing code. When it is on, the test set
alerts you when you send an incorrect command. You should turn it off once your code
is complete.
Set Operating Mode
There are four operating modes available: Active Cell, FDD Test Mode, CW Mode, or
Cell Off Mode.