CALL:FDDTest
CALL:FDDTest:DPCHannel:LEVel
Function
Sets/queries the dedicated physical channel's test mode power offset during FDD test mode
operation. This command sets the power offset level and turns on the power offset.
Setting
Range: -20.00 dB to 0 dB
Resolution: 0.01
Query
Range: -20.00 dB to 0 dB
Resolution: 0.01
*RST Setting
-10.3 dB
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:DPCHANNEL:LEVEL -7"
CALL:FDDTest:DPCHannel:STATe
Function
Sets/queries the dedicated physical channel's state during FDD test mode operation.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
1 (on)
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:DPCHANNEL:STATE OFF"
CALL:FDDTest:PICHannel[:SLEVel]
Function
Sets/queries the test mode power offset of the page indicator channel during FDD test mode
operation. This command sets the power offset level and turns on the power offset.
Setting
Range: -20.00 dB to 0 dB
Resolution: 0.01
Query
Range: -20.00 dB to 0 dB
Resolution: 0.01
*RST Setting
-8.3 dB
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:CPICHANNEL:SLEVEL -10"