Agilent Technologies 8960 Series Reference Manual page 259

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

CALL:DPCHannel:TYPe
Function
Sets/queries the dedicated physical control channel's channel type.
This setting cannot be changed while in active cell operating mode. Attempting to change this
setting while in this mode results in the following error message: "Command Rejected. Change
Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
Setting
Range: RMC12|RMC64
Query
Range: RMC12|RMC64
*RST Setting
RMC12
Requirements
Test Application Revision: A.01 and above
Test Application A.02 added RMC64
Programming Example
OUTPUT 714;"CALL:DPCHANNEL:TYPE RMC12" !Selects the 12.2 RMC for the DPCH.
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_hpib_call_dpchannel.fm
CALL:DPCHannel
259

Advertisement

Table of Contents
loading

Table of Contents