ABORt
ABORt[:ALL]
Function
Stops all measurements that are active.
If the trigger arm is set to single, the measurements will go to the idle state.
If the trigger arm is set to continuous, the measurements will re-arm and initiate again.
Setting
Range
• AFANalyzer - Audio Frequency measurements
• WACLeakage - Adjacent Channel leakage
• WBERror - Loopback Bit Error Ratio measurement
• WCDomain - Code Domain measurements
• WCPower - Channel Power measurement
• WOBWidth - Occupied Bandwidth measurement
• WSEMask - Spectrum Emission Mask measurement
• WTPower - Thermal Power measurement
• WWQuality - Waveform Quality measurement
Requirements
Test Application Revision: A.01 and above
Test Application Revision: A.02 added WCDomain, WSEMask, and WOBWidth.
Programming Example
OUTPUT 714;"ABORT:ALL" !Aborts all active measurements in progress.
ABORt:<meas-mnemonic>
Function
Stops the selected measurement if it is active.
If the trigger arm is set to single, the measurements will go to the idle state.
If the trigger arm is set to continuous the measurements will re-arm and initiate again.
Setting
Range
• AFANalyzer - Audio Frequency measurements
• WACLeakage - Adjacent Channel leakage
• WBERror - Loopback Bit Error Ratio measurement
• WCDomain - Code Domain measurements
• WCPower - Channel Power measurement
• WOBWidth - Occupied Bandwidth measurement
• WSEMask - Spectrum Emission Mask measurement
• WTPower - Thermal Power measurement
• WWQuality - Waveform Quality measurements
214