Setting Cell Parameters

Cell parameters are used to send base station location information on the downlink by specifying the following
values: mobile country code (MCC), mobile network code (MNC), and the local area code (LAC). They also
specify whether to use single or repeat paging when attempting to page the UE.

Changing Cell Parameters

Cell parameters typically do not change during base station operation. Therefore, these settings cannot be
changed during Active Cell operation. Instead, use the Cell Off operating mode when changing these settings.
See
"CALL[:CELL]:OPERating"

GPIB Commands for These Settings

• Mobile Country Code -
• Mobile Network Code -
• Local Area Code -
"CALL[:CELL]:LACode"
• Repeat Paging -
"CALL:PAGing"

Changing Cell Parameters From the Front Panel

1. Press the
CALL SETUP
2. Press the
key to display the available operating modes.
F1
3. Select Cell Off .
4. Press the
key (in the Call Control column), and then press Cell Parameters (
More
5. Select the desired parameter and enter the new value.