Call[:Cell]:Power - Agilent Technologies 8960 Series Reference Manual

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

CALL[:CELL]:POWer

CALL
:POWer
[:CELL]
"Diagram Conventions" on page 210
CALL[:CELL]:POWer[:SAMPLitude]
Function
Sets/queries the cell power level (including compensation for amplitude offset), and sets its state
to ON.
The cell power settings for the CW operating mode are independant of the cell power settings for
the other operating modes.
Setting
Range:
• -170dBm/3.84MHz to +37dBm/3.84MHz, 9.91 E+37
(-120 dBm/3.84MHz to -13 dBm/3.84MHz actual hardware range with amplitude offset = 0)
The actual power range is defined by adding the value of the associated Amplitude Offset to
the range in the table. For example, if amplitude offset is -3.5 dB, then the power range will
be -123.5 dBm/3.84 MHz to -16.5 dBm/3.84MHz.
Resolution: 0.01 dBm/3.84 MHz
Query
Range: Same as setting range.
Resolution: Same as setting range.
*RST Setting
9.91 E+37
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:CELL:POWER:SAMPLITUDE -30" !Sets the cell power level -30 dBm and turns it on.
[:SAMPlitude]
Complex Command
:AMPLitude
[:SELected]
:CW
:FDD
:STATe
[:SELected]
:CW
:FDD
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_hpib_call_power.fm
:CW
:FDD
<sp>1|ON|0|OFF
? (returns 1|0)
CALL[:CELL]:POWer
<sp><num value>[DBM]
?(returns num value)
<sp><num value>[DBM]
? (returns num value)
285

Advertisement

Table of Contents
loading

Table of Contents