CALL:CCPChannel
CALL:CCPChannel:SECondary:LEVel
Function
Sets/queries the secondary common control physical channel's initial power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this
setting while in this mode results in the following error message: "Command Rejected. Change
Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.
Setting
Range: -20.00 dB to 0 dB
Resolution: 0.01
Query
Range: -20.00 dB to 0 dB
Resolution: 0.01
*RST Setting
-6.9 dB
Requirements
Test Application Revision: A.02 and above.
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:LEVEL -5" !Sets the intial common control physical channel
level to -5 dB.
CALL:CCPChannel:SECondary:STATe
Function
Sets/queries the secondary common control physical channel's state.
This setting cannot be changed while in active cell operating mode. Attempting to change this
setting while in this mode results in the following error message: "Command Rejected. Change
Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
1 (on)
Requirements
Test Application Revision: A.02 and above.
Programming Example
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:STATE ON" !Enables the secondary common control physical
channel.