Agilent Technologies 8960 Series Reference Manual page 264

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

CALL:FDDTest
CALL:FDDTest:CLPControl:UPLink:MODE
Function
Sets/queries the uplink inner loop power control mode during FDD test mode operation.
When UP is selected, the test set sends all 0 (up) power control bits.
When DOWN is selected, the test set sends all 1 (down) power control bits.
When UDOWn is selected, the test set sends alternating up/down power control bits.
When UDOWn10 is selected, the test set sends alternating 10 up/down power control bits.
Setting
Range: UP|DOWN|UDOWn|UDOWn10
Query
Range:UP|DOWN|UDOW|UDOW10
*RST Setting
UDOW
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:CELL:CLPCONTROL:REVERSE:MODE UDOWN"
!Sets the closed loop power control mode to alternating up, down bits.
CALL:FDDTest:CCPChannel:PRIMary:STATe
Function
Sets/queries the primary common control physical channel's state during FDD test mode
operation.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
1 (on)
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:CCPCHANNEL:PRIMARY:STATE ON"
CALL:FDDTest:CPIChannel[:SLEVel]
Function
Sets/queries the test mode power offset of the common pilot channel during FDD test mode
operation. This command sets the power offset level and turns on the power offset.
Setting
Range: -20.00 dB to 0 dB
Resolution: 0.01
Query
Range: -20.00 dB to 0 dB
Resolution: 0.01
*RST Setting
-3.3 dB
Requirements
Test Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:CPICHANNEL:SLEVEL -10"
264
S:\Hp8960\E1963A WCDMA\4.0 release\Reference Guide\Chapters\wcdma_hpib_call_fddtest.fm

Advertisement

Table of Contents
loading