Regenerative Resistor Unit - YASKAWA SGM H Series User Manual

Servomotors
Table of Contents

Advertisement

(4) Dimensional Drawings
RH120/150/220
Units: mm (in)
D
B
A
C
φ4.5 (φ0.18)
Lead wire length L: 300 (11.81)
Model
Resistance
Rated Power
1 to 100 Ω
RH120
70 W
RH150
90 W
1 to 100 Ω
RH220
120 W
1 to 100 Ω
RH300C
Units: mm (in)
4.7 (0.19)
Lead wire length L: 300 (11.81)
Rated power: 200 W
Resistance: 1 to 10 kΩ

5.8.7 Regenerative Resistor Unit

(1) Models
The SERVOPACKs with a capacity of 6.0 kW or more do not have a built-in regenerative resistor.
The following regenerative resistor unit is required according to the SERVOPACK model.
SERVOPACK Model
SGDM-60ADA
SGDM-75ADA to -1EADA
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
D
A
B
C
D
E
F
Dimensions
RH120
182 150 172 16 42 22 20
(7.17) (5.91) (6.77) (0.63) (1.65) (0.87) (0.79)
RH150
212 180 202 16 44 24 30
(8.35) (7.09) (7.95) (0.63) (1.73) (0.94) (1.18)
RH220
230 200 220 15 60 24 20
(9.06) (7.87) (8.66) (0.59) (2.36) (0.94) (0.79)
312 (12.28)
270 (10.63)
300 (11.81)
Regenerative Resistor
Unit Model
JUSP-RA04
JUSP-RA05
Units: mm (in)
138 (5.43)
170 (6.69)
154 (6.06)
G
Lead wire length L: 500 (19.69)
Rated power: 120 W
Resistance: 1 to100 Ω
Units: mm (in)
250 (9.84)
234 (9.21)
218 (8.58)
Lead wire length L: 450 (17.72)
Rated power: 300 W
Resistance: 1 to 30 Ω
Specifications
Power Loss
6.25 Ω, 880 W
3.13 Ω, 1760 W
5.8 Peripheral Devices
RH220B
×
φ4.5 (φ0.18)
4
RH500
2 - M3
3
(0.12)
φ4.5 (φ0.18)
2
×
Allowable
180 W
350 W
5-65
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdm seriesSgmahSgmphSgmghSgmshSgmdh ... Show all

Table of Contents