10 Upgraded Versions

10.5.2 Switches

* 1. After changing these parameters, turn OFF the control power supply and then turn it ON again to enable the
new settings.
* 2. The upper limit differs depending on the resolution (number of bits) of the encoder connected to SERVOPACK.
Upper Limit: (2 numbers of encoder bits) / 4
When no encoder is connected, the value in the above list is the upper limit.
For further information on the restrictions, refer to 10.3.2 Improvement of Dividing Output Resolution.
The factory setting is 0001 for the models with 5 kW or more.
* 3. The factory setting is 0001 for the models with 5 kW or more.
Note: The specifications shown in shaded column are the modified items.
10.5.2 Switches
Parameter
Pn10B
n. 0
n. 1
n. 2
n. 3
Pn207
n. 0
n. 1
Pn218
n.
n.
Pn408
n. 0
n. 1

10.5.3 Input Signal Selection

Parameter
Pn513
n.
n.
n.
n.
n.
n.
n.
n.
n.
n.
n.
n.
n.
n.
n.
n.
* After changing the setting, turn OFF the power and ON again to enable the new setting.
10-20
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Automatic gain switching disabled (Factory setting)
Switches the gain according to the position reference condition only.
Switches the gain according to the position error condition only.
Switches the gain according to the position reference and position error condition only.
Uses the parameter Pn201 (For 16-bit or less) as the dividing ratio (Factory setting).
Uses the parameter Pn212 (For 17-bit or more) as the dividing ratio.
0
Reference pulse input multiplication switching function: Disabled (Factory setting)
1
Reference pulse input multiplication switching function: Enabled
Second notch filter disabled.
Uses second notch filter.
0
ON when CN1-40 input signal is ON (L-level).
1
ON when CN1-41 input signal is ON (L-level).
2
ON when CN1-42 input signal is ON (L-level).
3
ON when CN1-43 input signal is ON (L-level).
4
ON when CN1-44 input signal is ON (L-level).
5
ON when CN1-45 input signal is ON (L-level).
6
ON when CN1-46 input signal is ON (L-level).
7
Sets signal ON.
8
Sets signal OFF. (Factory setting)
9
ON when CN1-40 input signal is OFF (H-level).
A
ON when CN1-41 input signal is OFF (H-level).
B
ON when CN1-42 input signal is OFF (H-level).
C
ON when CN1-43 input signal is OFF (H-level).
D
ON when CN1-44 input signal is OFF (H-level).
E
ON when CN1-45 input signal is OFF (H-level).
F
ON when CN1-46 input signal is OFF (H-level).
Meaning