YASKAWA SGM H Series User Manual page 596

Servomotors
Table of Contents

Advertisement

12 Appendix
12.3.2 List of Parameters
Parameter
No.
Pn50A
Input Signal Selections 1
4th
3rd
digit
digit
n.
12-36
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Name
2nd
1st
digit
digit
Input Signal Allocation Mode
(Refer to "7.3.2 Input Circuit Signal Allocation.")
Uses the sequence input signal terminals with standard allocation. ∗
0
1
Changes the sequence input signal allocation for each signal.
/S-ON Signal Mapping
Signal Polarity: Normal; Servo ON when ON (L-level)
Signal Polarity: Reverse; Servo ON when OFF (H-level)
(Refer to "8.3.1 Setting the Servo ON Signal.")
0
ON when CN1-40 input signal is ON (L-level).
1
ON when CN1-41 input signal is ON (L-level).
2
ON when CN1-42 input signal is ON (L-level).
3
ON when CN1-43 input signal is ON (L-level).
4
ON when CN1-44 input signal is ON (L-level).
5
ON when CN1-45 input signal is ON (L-level).
6
ON when CN1-46 input signal is ON (L-level).
7
Sets signal ON.
8
Sets signal OFF.
9
OFF when CN1-40 input signal is OFF (H-level).
A
OFF when CN1-41 input signal is OFF (H-level).
B
OFF when CN1-42 input signal is OFF (H-level).
C
OFF when CN1-43 input signal is OFF (H-level).
D
OFF when CN1-44 input signal is OFF (H-level).
E
OFF when CN1-45 input signal is OFF (H-level).
F
OFF when CN1-46 input signal is OFF (H-level).
/P-CON Signal Mapping (P control when ON (L-level))
(Refer to "9.4.4 Proportional Control Operation (Proportional Operation Reference).")
0 to F Same as /S-ON
P-OT Signal Mapping (Overtravel when OFF (H-level))
(Refer to "8.3.3 Setting the Overtravel Limit Function.")
0
Forward run allowed when CN1-40 input signal is ON (L-level).
1
Forward run allowed when CN1-41 input signal is ON (L-level).
2
Forward run allowed when CN1-42 input signal is ON (L-level).
3
Forward run allowed when CN1-43 input signal is ON (L-level).
4
Forward run allowed when CN1-44 input signal is ON (L-level).
5
Forward run allowed when CN1-45 input signal is ON (L-level).
6
Forward run allowed when CN1-46 input signal is ON (L-level).
7
Forward run prohibited.
8
Forward run allowed.
9
Forward run allowed when CN1-40 input signal is OFF (H-level).
A
Forward run allowed when CN1-41 input signal is OFF (H-level).
B
Forward run allowed when CN1-42 input signal is OFF (H-level).
C
Forward run allowed when CN1-43 input signal is OFF (H-level).
D
Forward run allowed when CN1-44 input signal is OFF (H-level).
E
Forward run allowed when CN1-45 input signal is OFF (H-level).
F
Forward run allowed when CN1-46 input signal is OFF (H-level).
Setting Range
Unit
Factory
Setting
Reference
Setting
Validation
Section
After
2100
restart