6.4.4 Installation Conditions of UL Standards

(c) Fixing the Cable
Fix and ground the cable shield using a piece of conductive metal.
• Example of Cable Clamp
Host controller side
(d) Shield Box
A shield box, which is a closed metallic enclosure, should be used for shielding magnetic interference. The
structure of the box should allow the main body, door, and cooling unit to be attached to the ground. The box
opening should be as small as possible.
6.4.4 Installation Conditions of UL Standards
To adapt the following SERVOPACKs to UL Standards, use a corresponding terminal kit for cables to connect
the terminals described in the table below.
SERVOPACK Model
SGDM-50ADA (-R)
SGDM-60ADA (-P)
SGDM-75ADA (-P)
SGDM-1AADA (-P)
SGDM-1EADA (-P)
Main Circuit Wiring
IMPORTANT
1. SGDM SERVOPACKs are suitable under the following conditions.
2. SERVOPACKs must be used with UL-listed fuses or circuit breakers, in accordance with the National
3. Use 75°C heat-resistant copper wires or an equivalent.
6-24
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Ground plate
Connection Terminals
L1, L2, L3
(Main circuit power supply input)
U, V, W (Motor Output)
• With 200 V class: Less than 5000 A
• With 400 V class: Less than 5000 A
Electrical Code (NEC).
Cable
Shield (cable sheath stripped)
Fix and ground the cable shield
using a piece of conductive metal.
Cable
clamp
Remove paint on mounting surface.
Terminal Kit Model
JZSP-CKT75
JZSP-CKT75
JZSP-CKT75
JZSP-CKT75
JZSP-CKT1E
, 240 V maximum.
rms
, 480 V maximum.
rms