Servopack's Parts Replacement Schedule - YASKAWA SGM H Series User Manual

Servomotors
Table of Contents

Advertisement

11 Inspection, Maintenance, and Troubleshooting

11.2.3 SERVOPACK's Parts Replacement Schedule

11.2.3 SERVOPACK's Parts Replacement Schedule
The following electric or electronic parts are subject to mechanical wear or deterioration over time. To avoid
failure, replace these parts at the frequency indicated.
Refer to the standard replacement period in the following table, contact your Yaskawa representative. After
an examination of the part in question, we will determine whether the parts should be replaced or not.
The parameters of any SERVOPACKs overhauled by Yaskawa are reset to the factory settings before ship-
ping. Be sure to confirm that the parameters are properly set before starting operation.
Cooling Fan
Smoothing Capacitor
Relays
Fuses
Aluminum Electrolytic
Capacitor on Circuit Board
11-22
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table 11.8 Periodical Part Replacement
Part
Standard Replacement
4 to 5 years
7 to 8 years
Period
• Ambient Temperature: Annual average of 30°C
• Load Factor: 80% max.
• Operation Rate: 20 hours/day max.
10 years
5 years
Operating Conditions

Advertisement