Reference Pulse Input Multiplication Switching Function - YASKAWA SGM H Series User Manual

Servomotors
Table of Contents

Advertisement

10 Upgraded Versions

10.3.3 Reference Pulse Input Multiplication Switching Function

(2) Setting PG dividing ratio of 5-digit or more
The following table shows a procedure to set Pn212 by a digital operator or a panel operator.
Proce-
Display After
dure
Operation
1
2
3
(Blinks)
4
(Blinks)
5
6
When the password setting (write prohibited setting) is enabled, the setting can be read only by pressing Left or Right
INFO
Cursor Key.
10.3.3 Reference Pulse Input Multiplication Switching Function
If the /PSEL signal for switching the multiplication of the position reference pulse input turns ON or OFF, the
multiplication factor can be switched from 1 to n (n = 1 to 99). And the status of this signal indicates whether the
position multiplication is switched to 1 or n.
Set Pn218.0 = 1 to enable this function, and set the multiplication in Pn217.
To change the reference pulse multiplication, the position reference pulse must be set to 0. Otherwise, the opera-
tion cannot be guaranteed.
10-10
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Hand-held
Panel Operator
digital operator
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
DATA
ENTER
DATA/
(DATA/ENTER Key)
(DATA/SHIFT Key)
DATA/
(DATA/SHIFT Key)
(Press at least
one second.)
DATA/
(DATA/SHIFT Key)
(Press at least
one second.)
DATA
DATA/
ENTER
(DATA/SHIFT Key)
(DATA/ENTER Key)
(Press at least
one second.)
Description
Press DSPL/SET Key to select the utility function mode.
Select the parameter Pn212.
Press Left or Right Cursor Key to select the digit. The
enabled digit blinks.
Press Up or Down Cursor Key to change the value.
Press DATA/ENTER Key to display the lower 5 digits of
the current PG dividing ratio setting value.
Press Left or Right Cursor Key once, or DATA/SHIFT Key
for more than one second to select the digit. The enable
digit blinks.
Press Up or Down Cursor Key to change the value.
Pressing Left or Right Cursor Key or DATA SHIFT Key
when the left-end or right-end digit is blinking displays
another 5 digits.
Press Left or Right Cursor Key or DATA/SHIFT Key to
select the digit. The enabled digit blinks.
Press Up or Down Cursor Key to change the value.
Pressing Left or Right Cursor Key or DATA/SHIFT Key
when the left-end or right-end digit is blinking displays
another 5 digits.
Repeat the steps 4 and 5 to change the data.
DATA/ENTER Key once, or DATA/SHIFT Key for more
than one second.
The display returns to Pn212.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdm seriesSgmahSgmphSgmghSgmshSgmdh ... Show all

Table of Contents