Section 8 8-Bit PWM Timer (PWMU)
8.3
Register Descriptions
The PWMU has the following registers.
Table 8.2
Register Configuration
Channel
Register Name
Channel A
PWM control register A_A
(for clock control)
PWM control register B_A
(for output control)
PWM control register C_A
(for mode control)
PWM control register D_A
(for phase control)
PWM prescaler register 0_A
PWM prescaler register 1_A
PWM prescaler register 2_A
PWM prescaler register 3_A
PWM prescaler register 4_A
PWM prescaler register 5_A
PWM duty setting register 0_A
PWM duty setting register 1_A
PWM duty setting register 2_A
PWM duty setting register 3_A
PWM duty setting register 4_A
PWM duty setting register 5_A
Rev. 1.00 Apr. 28, 2008 Page 200 of 994
REJ09B0452-0100
Abbreviation
R/W
PWMCONA_A R/W
PWMCONB_A R/W
PWMCONC_A R/W
PWMCOND_A R/W
PWMPRE0_A
R/W
PWMPRE1_A
R/W
PWMPRE2_A
R/W
PWMPRE3_A
R/W
PWMPRE4_A
R/W
PWMPRE5_A
R/W
PWMREG0_A
R/W
PWMREG1_A
R/W
PWMREG2_A
R/W
PWMREG3_A
R/W
PWMREG4_A
R/W
PWMREG5_A
R/W
Data
Initial
Bus
Value
Address
Width
H'00
H'FD0C
8
H'00
H'FD0D
8
H'00
H'FD0E
8
H'00
H'FD0F
8
H'00
H'FD01
8
H'00
H'FD03
8
H'00
H'FD05
8
H'00
H'FD07
8
H'00
H'FD09
8
H'00
H'FD0B
8
H'00
H'FD00
8
H'00
H'FD02
8
H'00
H'FD04
8
H'00
H'FD06
8
H'00
H'FD08
8
H'00
H'FD0A
8