7.2 Parameter list
p4095

PM330 digital inputs simulation mode / PM330 DI sim_mode

G120X_DP (PM330),
Access level: 3
G120X_PN (PM330),
Can be changed: T, U
G120X_USS (PM330)
Unit group: -
Min:
-
Description:
Sets the simulation mode for digital inputs of the PM330 power unit.
Bit field:
Bit
00
01
02
03
Dependency:
The setpoint for the input signals is specified using p4096.
See also: p4096
Note
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
p4096

PM330 digital inputs simulation mode setpoint / PM330 DI sim setp

G120X_DP (PM330),
Access level: 3
G120X_PN (PM330),
Can be changed: T, U
G120X_USS (PM330)
Unit group: -
Min:
-
Description:
Sets the setpoint for the input signals in the digital input simulation mode of the PM330 power unit.
Bit field:
Bit
00
01
02
03
Dependency:
The simulation of a digital input is selected using p4095.
See also: p4095
Note
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
p5350[0...n]

Mot_temp_mod 1/3 boost factor at standstill / Standst boost_fact

Access level: 2
Can be changed: T, U
Unit group: -
Min:
1.0000
854
Signal name
DI 0 (X9.3, external alarm)
DI 1 (X9.4, external fault)
DI 2 (X9.5, Emergency Off category 0)
DI 3 (X9.6, Emergency Off category 1)
Signal name
DI 0 (X9.3, external alarm)
DI 1 (X9.4, external fault)
DI 2 (X9.5, Emergency Off category 0)
DI 3 (X9.6, Emergency Off category 1)
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Simulation
Simulation
Simulation
Simulation
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
High
High
High
High
Calculated: -
Scaling: -
Unit selection: -
Max:
2.0000
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
0000 bin
0 signal
FP
Terminal eval
-
Terminal eval
-
Terminal eval
-
Terminal eval
-
Data type: Unsigned32
Dynamic index: -
Function diagram: 2275
Factory setting:
0000 bin
0 signal
FP
Low
-
Low
-
Low
-
Low
-
Data type: FloatingPoint32
Dynamic index: MDS, p0130
Function diagram: 8017
Factory setting:
2.0000