Pn Name Of Station / Pn Name Stat; Pn Ip Address / Pn Ip Addr; Pn Default Gateway / Pn Def Gateway; Pn Subnet Mask / Pn Subnet Mask - Siemens SINAMICS G120X Operating Instructions Manual

Infrastructure converter for hvac/water/wastewater
Hide thumbs Also See for SINAMICS G120X:
Table of Contents

Advertisement

Parameters
7.2 Parameter list
p8920[0...239]

PN Name of Station / PN Name Stat

G120X_PN
Access level: 3
Can be changed: T, U
Unit group: -
Min:
-
Description:
Sets the station name for the onboard PROFINET interface on the Control Unit.
The actual station name is displayed in r8930.
Dependency:
See also: p8925, r8930
Note
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
PN: PROFINET
p8921[0...3]

PN IP address / PN IP addr

G120X_PN
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0
Description:
Sets the IP address for the onboard PROFINET interface on the Control Unit.
The actual IP address is displayed in r8931.
Dependency:
See also: p8925, r8931
Note
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8922[0...3]

PN Default Gateway / PN Def Gateway

G120X_PN
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0
Description:
Sets the default gateway for the onboard PROFINET interface on the Control Unit.
The actual standard gateway is displayed in r8932.
Dependency:
See also: p8925, r8932
Note
The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8923[0...3]

PN Subnet Mask / PN Subnet Mask

G120X_PN
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0
Description:
Sets the subnet mask for the onboard PROFINET interface on the Control Unit.
The actual subnet mask is displayed in r8933.
882
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
255
Calculated: -
Scaling: -
Unit selection: -
Max:
255
Calculated: -
Scaling: -
Unit selection: -
Max:
255
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: Unsigned8
Dynamic index: -
Function diagram: -
Factory setting:
-
Data type: Unsigned8
Dynamic index: -
Function diagram: -
Factory setting:
0
Data type: Unsigned8
Dynamic index: -
Function diagram: -
Factory setting:
0
Data type: Unsigned8
Dynamic index: -
Function diagram: -
Factory setting:
0