Co/Bo: Closed-Loop Cascade Control Status Word / Csc_Ctrl Zsw; Closed-Loop Cascade Control Operating Hours / Csc_Ctrl Op_Hrs; Closed-Loop Cascade Control Max Time For Continuous Operation; Closed-Loop Cascade Control Operating Time Limit - Siemens SINAMICS G120X Operating Instructions Manual

Infrastructure converter for hvac/water/wastewater
Hide thumbs Also See for SINAMICS G120X:
Table of Contents

Advertisement

r2379.0...7

CO/BO: Closed-loop cascade control status word / Csc_ctrl ZSW

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the status word of the closed-loop cascade control
Bit field:
Bit
00
01
02
03
04
05
06
07
p2380[0...2]

Closed-loop cascade control operating hours / Csc_ctrl op_hrs

Access level: 3
Can be changed: T, U
Unit group: -
Min:
0.0 [h]
Description:
Displays the operating hours for the external motors.
The display can only be reset to zero.
Index:
[0] = Motor 1
[1] = Motor 2
[2] = Motor 3
p2381
Closed-loop cascade control max time for continuous operation / Csc_ctrl t_max
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0.1 [h]
Description:
Time limit for the continuous operation of external motors.
Continuous operation is measured starting from when a motor is connected to the line voltage. It ends when a motor
is disconnected from the line.
p2382
Closed-loop cascade control operating time limit / Csc_ctrl t_max op
Access level: 3
Can be changed: T, U
Unit group: -
Min:
0.1 [h]
Description:
Limit for the total operating time of external motors.
The total operating time of an external motor increases every time it is switched in.
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Signal name
Start external motor 1
Start external motor 2
Start external motor 3
Switch-in motor
Switch-in/switch-out active
All motors active
Automatic replacement not possible
Alarm active
Calculated: -
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max:
340.28235E36 [h]
Calculated: -
Scaling: -
Unit selection: -
Max:
100000.0 [h]
Calculated: -
Scaling: -
Unit selection: -
Max:
100000.0 [h]
Parameters
7.2 Parameter list
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Factory setting:
0.0 [h]
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Factory setting:
24.0 [h]
Data type: FloatingPoint32
Dynamic index: -
Function diagram: -
Factory setting:
24.0 [h]
819