Parameters
7.2 Parameter list
16
17
18
19
20
21
22
23
24
26
Dependency:
See also: r3925
Note
The parameter is a copy of p1909.
r3928[0...n]
Rotating measurement configuration / Rot meas config
Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Successfully completed component of the last rotating measurement carried out.
Bit field:
Bit
01
02
03
04
05
11
12
13
14
Dependency:
See also: r3925
Note
The parameter is a copy of p1959.
r3929[0...n]
Motor data identification modulated voltage generation / MotID U_gen mod
Access level: 4
Can be changed: -
Unit group: -
Min:
-
Description:
Configuration of voltage generation for the various MotID sections in the case of the most recent successful MotID.
Bit field:
Bit
00
01
02
03
848
Short motor identification (lower quality)
Measurement without control parameter calculation
After motID direct transition into operation
After MotID automatically save results
Estimate cable resistance
Calibrating the output voltage measurement
Only identify circle
Deactivate circle identification
Circle identification with 0 and 90 degrees
Measure with long cable
Signal name
Saturation characteristic identification
Moment of inertia identification
Re-calculates the speed controller parameters
Speed controller optimization (vibration test)
q leakage inductance ident. (for current controller adaptation) Yes
Do not change the controller parameters during the
measurement
Measurement shortened
After measurement direct transition into operation
Calculate speed actual value smoothing time
Signal name
Wobble U_generate to determine dead-time correction
Wobble U_generate to determine stator resistance
Wobble U_generation to determine rotor time constant
Wobble U_generation to determine leakage inductance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: CALC_MOD_ALL Data type: Unsigned16
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: CALC_MOD_ALL Data type: Unsigned32
Scaling: -
Unit selection: -
Max:
-
1 signal
Yes
Yes
Yes
Yes
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Dynamic index: DDS, p0180
Function diagram: -
Factory setting:
-
0 signal
FP
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
Dynamic index: DDS, p0180
Function diagram: -
Factory setting:
-
0 signal
FP
No
-
No
-
No
-
No
-
SINAMICS G120X converter